dc.contributor | General Motors | en_US |
dc.contributor.author | Hector, Lou | |
dc.contributor.author | Alturk, Rakan | |
dc.contributor.other | louis.hector@gm.com | en_US |
dc.date.accessioned | 2016-09-22T12:45:43Z | |
dc.date.available | 2016-09-22T12:45:43Z | |
dc.identifier.citation | None yet | en_US |
dc.identifier.uri | http://hdl.handle.net/11256/823 | |
dc.description.abstract | A General Motors Instron VHS 2-Column Servo-Hydraulic Test Unit with High Speed Stereo Digital Image Correlation for strain measurement and dual strain gauges for load measurement were used. Materials were tested at room temperature and nominal strain rate of 0.5/s, 5/s, 50/s and 500/s. Data file consists of a true stress, true strain, engineering stress and engineering strain data. | en_US |
dc.description.sponsorship | DOE-EE00059676 | en_US |
dc.relation | None yet | en_US |
dc.relation.haspart | None yet | en_US |
dc.relation.isbasedon | None yet | en_US |
dc.relation.uri | No | en_US |
dc.rights | CC0 1.0 Universal | * |
dc.rights.uri | http://creativecommons.org/publicdomain/zero/1.0/ | * |
dc.subject | High strain rate, Servo-hydraulic, strain gauge, digital image correlation, Medium Mn Trip Steel, true stress, true strain | en_US |
dc.title | High strain rate data for Medium Mn 2 (10 Wt. % Mn) Steel | en_US |
dc.type | Dataset | en_US |